COCERSI · Contamination in drinking water distribution systems: Consumer exposure risks and source identification
FP6 — Marie Curie Actions (Human Resources and Mobility)
- Duration
- 2005-04-15 → 2007-04-14
- EU contribution
- €80,000
- Participants
- 1
- Scheme
- IRG
Lines connect the coordinator with its partners. CORDIS does not always give exact coordinates for projects before 2014. These points are placed at city or country level.
Results in brief
Final Activity Report Summary - COCERSI (Contamination in drinking water distribution systems: Consumer exposure risks and source identification)
Vulnerability of drinking water distribution systems (DWDS) to contamination events has been always a major concern of water utilities and regulatory agencies. This research project developed along three main interacting topics. One is the development of methods to identify optimal sensor location for early warning should a contamination event occur. Second topic is the contamination source identification should a contamination event occur and be detected in the system. Third line of research has been the study of the efficacy against a contamination event of disinfectant residual maintenance in the distributed water and the trade-offs of these strategies to reduce consumer exposure risks. In addition, some work has been carried out the improve water quality modelling trough sampling design and disinfectant residual monitoring within the distribution system. This part is critical for all other topics, since operational research in this area has to rely on good models to mimic real dynamical conditions. The most recent approaches that have been proposed for sensor location design in DWDS have different mathematical formulations and require different computational efforts; both depending on design objectives, simplifying assumptions and solution methods adopted. The main goal of the work developed has been instead to propose a model to identify optimal water quality monitoring locations in DWDS that somehow unifies the different approaches in a unique coherent general framework, applicable to steady or unsteady flow conditions, and that may accommodate different design objectives. Various design objectives may be described as identical mixed-integer linear programs whose formulation differences are only the cost function coefficients and not the decision variables nor the constraints. The model proposed may reproduce equal solutions of most recent approaches when design characteristics -- in particular design objective, network dynamical properties and contamination ensembles -- are set equal. Recently, there is a grown interest in investigating methodologies that may allow using the gathered information obtained by the sensors to identify the locations or the network areas from which the contamination might have started. Such capability could be very important both for emergency response strategies, for example to isolate only part of the network rather than affecting the entire DWDS; but more importantly to better investigate, and possibly eliminate once for all, the cause of contamination. The main challenges of this problem are the inherent non-uniqueness of the solution due to limited data availability compared to the typical size of a real DWDS; and the computational effort required to solve the problem due to the significant number of space and time variables. Research activity has developed along two main topics: (1) sampling design to optimal identify sensor locations that may improve inversion; (2) the implementation and comparison of different approaches (Least-Squares, Bayesian and Entropic) for solving ill-posed inverse problems for assigned sensor networks. Finally, early detection technologies will become available for installation in the coming years. Therefore, it is necessary to address several issues associated with the use of warning systems and residual maintenance design. A holistic simulation framework for designing protection strategies has been proposed. A focal point of the work is how residual maintenance can be tailored keeping into account of the presence of a warning system and vice-versa. A multi-species network water quality model that includes disinfectant decay and disinfection kinetics quantitatively assesses the risk of delivering contaminated water to consumers. For an assumed set of intrusion scenarios, the system vulnerability is quantified as the cumulative distribution function of the number of consumers that receive contaminated water before the warning system raises an alarm. Design and effectiveness of these consumer protection measures are discussed and illustrated by applying the framework on example networks
Data: CORDIS, © European Union
Project objective
There is a growing debate among research and practice communities on adequate strategies that reduce consumer exposure to accidental microbial contaminations or deliberate attacks in drinking water distribution systems (DWDS). To limit the spread of disease in a contamination event, effective strategies are multi-barrier approaches that include prevention, detection, mitigation and source elimination.Typically, early public health protection relies on the passive efficacy of a disinfectant residual. However, little is known on its real ability to successfully inactivate intruding pathogens in the DWDS before water reaches consumers. A second barrier is provided by rapid and adequate response to emergency scenarios.To this aim, an automatic sensor system t o continuously monitor water quality in DWDS would be very important as an early detection system and for contamination source location identification to eliminate or isolate the source problems. First preliminary objective is the development of a general method that, through the use of water quality modelling, systematically and quantitatively measures the ability of a particular system operation design to reduce consumer exposure to hazardous contaminations in DWDS.Second objective is to explicitly use t he vulnerability assessment scheme to compare and select alternative system operation designs that may preventively provide an improved barrier to protect consumers until a contamination event is detected and consequent action is taken. This scheme will al so allow for the evaluation of adequate mitigation strategies to be adopted once water quality problems have been detected.Finally, a methodology and tool set will be developed to identify the optimal sensor layout that, from the one hand reduces consumer exposure risks to contaminations and from the other hand is able to provide valuable information to identify, at least statistically, network zones that may be the cause of water quality problems.
Original text from CORDIS.
Participants
- CENTRE NATIONAL DU MACHINISME AGRICOLE, DU GÉNIE RURAL DES EAUX ET DES FORÊTS · ANTONYCoordinatorCity levelFrance
Links
Data: CORDIS, © European Union